Elgas Electronic Volume Converter – Elcor

Brand Elgas
Model Electronic Volume Converter – Elcor
Specification Key Features & Benefits
• Single-channel gas volume corrector for precise measurement
• Modular design for flexible applications
• High accuracy & stability over long-term operation
• Long battery life: Corrector up to 11 years, Modem up to 11 years (HB-03D)
• Pressure measurement up to 130 bar
• Large storage capacity for historical data
• IP66 weather-resistant enclosure for outdoor use
• Operating temperature range down to -40°C
• Multiple display options: Graphical display & always-on segment display
• Easy configuration with COMPASS or TELVES software
• Certified for hazardous zones 0, 1, and 2Compliance & Certification
• MID Metrological Approval: TCM 143 / 18-5562
• ATEX Certification: FTZÚ 17 ATEX 0143X

Communication Features
• Three independent communication interfaces (up to 115,200 Bd)
• Optional integrated modem: 2G, 3G, 4G, NarrowBand (NB)
• Supports external modems via serial interface
• Optical interface IEC 62056-21 / IEC-1107 (115,200 Bd)
• Integrated RS232 / RS485 + optional RS232 module

Input / Output Capabilities
• 3 Digital Inputs: Low-frequency pulse or binary signals
• 2 Digital Outputs: Configurable for pulse/binary signals
• Up to 2 Analog Outputs via CLO module (4–20mA)
• Optional Encoder Interface: NAMUR or SCR+ encoders

Optional Accessories & Modules
• Temperature & Pressure Enhancements: Thermowell, welded mounting kit, DN3 PN100 three-way valve
• Optical Communication Head HIE-04 mod B (9600–115,200 Bd, USB 2.0)
• Configuration Software: COMPASS & TELVES
• Internal Modules: NAMUR, SCR, M2G Modem (2G GSM/GPRS), M4G Modem (4G LTE Cat M1), COM0 RS232
• External Modules: B-RS intrinsically safe RS485/RS232, B-DO intrinsically safe digital outputs, CLO 4–20mA current output module

Add to Quote